Fire Curtains Limited  0044 (0)116 232 0108

 

BS 476: Part 22 Warrington Global Safety. UK

     BS EN 1634-1: 2000 Warrington Global Safety. UK

        BS 476: 1987 Part 8 Warrington Global Safety. UK.

    BS EN 1634-1: 2000 Chiltern Fire. Corner & Over-lapping Curtains. 

    Annex D of PAS 121:2007 BRE Global. 

BS 7346: Part 3  Warrington FRC, UK. BS476: Part 22, Warrington FRC, UK. 

Warrington Middle East Certification.

1hr,  2hr,  4hr, fire integrity. 30 minute and 57 minute "insulation zone" curtains.

World-wide Suppliers & Installers of automatic fire & smoke  curtains

Smoke curtain / Fire Curtains / blinds /screens fire barriers

 

 

A fire curtain, manufactured and installed by Fire Curtains Ltd, Leicester, and being tested before handing over to our client in London.

 

 

 This photograph is the property of Fire Curtains Ltd



 


Distributors and partners in various parts of the world, For details of your local distributor please call our UK head office. 00 44 116 232 0108
 

The new European standards, which are now being introduced gradually, relate to the requirement that "insulated zone fire curtains" should be to the specifications of PAS 121. These fire curtains should have an insulation value of 30 minutes and 30 minutes integrity, as per the requirements of PAS 121.

During all three of our fire tests the temperature on the safe side of the fire curtain rose only by 45 degrees Celsius, at a point 100mm away from the curtain. And this was after 30 minutes and at 1000 degrees Celsius on the fire side.

The difference between our competitors standard curtain and our (PAS121 specification) insulation curtain may probably be a life saving difference.

Do not take a chance, Use our (PAS 121 specification) "insulated zone fire curtains"


  • 128 Station Road
  • Leicester. LE3 8BR
  • Tel. 0116 232 0108
  • Fax 0116 287 8426
  • e-mail to firecurtains@mail.com
  •  

 

 BENEFITS OF DEALING DIRECTLY WITH FIRE CURTAINS LTD

  1. Excellent value for money.
  2. Quick turn around time. 3 to 10 working days if urgent.
  3. Same day or instant quotations.
  4. Trade enquiries are most welcome.
  5. Units built in our factory, prepared for installation and can be installed by most general workers with the help of our installation instructions.
  6. Our installers are all factory trained and are IPAF trained on various equipment.
  7. Nationwide supply and installation.
  8. FREE advice & specifications, just send an e-mail. 
  9. Free details on our automatic smoke or fire curtains.
  10. Controlled descent & gravity fail-safe options.
  11. Delayed action controls & split level drops options.
  12. Servery Curtain Specialists.  No extra's charged for made to measure orders.
  13. Static Smoke and Fire Curtain Specialists.
  14. No job too large or too small.

 

How valuable, irreplaceable or expensive are the contents of your building? We are here to help you avoid the unthinkable. No obligation, just free information. firecurtains@mail.com

 

The following photographs are the property of Fire Curtains Ltd and may not be used by other companies.

Smoke & Fire Curtains / blinds

Our 2hr curtain under test.

Our fire curtains provide the benefits of an off the shelf lightweight design which eliminates the problems of steel shutters.

The Fire curtain requires less preparation time and no special steelwork structure to install.

The weighted bar sags down the curtain and is inserted to test for curtains up to 8m high.

 Smoke curtain / Fire Curtains / blinds /screens fire barriers

 

 

A Fire Curtains Ltd installation which involves multiple barrels.

The finished result of a multiple barrel fire curtain installation. This view from a corner.

Smoke curtain / Fire Curtains / blinds /screens fire barriers

Designed for openings of up to 30m wide by 8m high in the fire compartment wall.  It eliminates the dangers posed by heavy steel shutters which could drop and cause serious injuries or even fatalities.

It is especially suited to clean hygienic environments such as kitchens and hospitals, or is equally at home over windows and reception areas

The Fire Curtains Ltd Fire Curtain is tested to BS476 Part 22, One hour and Two hour fire curtain performance and BS7346 Part 3 for smoke.

The following photographs are the property of Fire Curtains Ltd and may not be used by other companies.

Completing a fire curtain installation

Completing an installation in a large departmental store out of hours. Enquiry on Monday and fitted on Thursday.

 

 

 

Smoke & Fire Curtains / blinds

Portugal, A Standard Fire Curtain being installed in a Theatre.

Theatre curtains.

 

Servery or hatchway fire curtains.   Made to your drawings specifications.

Not standard sizes but made to withing 5mm of your specifiactions.

Delivery 2 to 5 working days.

Slim, lightweight, easy to install and made to measure sizes.
2hour fire resistance to BS476 Part 22 and Smoke control to BS7346 Part 3
Sealed to prevent the passage of fire or smoke

24V operation with battery back-up.

Options available.

Choice of alarm actuations and fire/smoke sensors.
Powder coating in any standard RAL colour
 
Gravity fail-safe motor options.

Automatic smoke curtains are not just an adjunct to smoke ventilation systems. They are an essential safety component, designed to protect life and help save lives, by containing and stopping the spread of lethal, superheated, noxious gases.

Fail Safe Option.

Our battery back up smoke and fire curtains are designed to close down  the openings when activated by a fire signal. These are also the option of special units which are designed to be gravity  fail safe, even without any power in the building, the back-up batteries will not only allow the curtains to fall once the required signal has been received but also in a total power failure.

Smoke curtains & fire curtains are classified by various test bodies.

Smoke Curtains.

BS 7346: Part 3  Warrington FRC, UK. BS476: Part 22, Warrington FRC, UK.

Fire Curtains.

BS 476: Part 22 Warrington Global Safety. UK.

     BS EN 1634-1: 2000 Warrington Global Safety. UK.

    WarringtonMiddle East Certification.

    BS 476: 1987 Part 8 Warrington Global Safety. UK.

    BS EN 1634-1: 2000 Chiltern Fire. Corner & Over-lapping Curtains.

    Annex D of PAS 121:2007 BRE Global.

 

firecurtains@mail.com